ERD620- FACE IMAGE
Large Color Display Maximum Performance Multiple Communication

ERD620NEW COMPACT VALVES TESTER

After 46 years, and 275,000 testers installed in more than 5,000 customers worldwide, ATEQ presents its revolutionnary valves tester ERD620.

New electronic module, new measurement module, new interface, new accessories… All has been made to improve your quality control.

The purpose of the instrument is to generate a pressure ramp and is waiting for an event as a flow appears (ex: valve opening). A ramp down can also detect when valve is closed. The instrument will display the event pressures and compare them to reject levels. As an option the flow event can be replaced by a dry contact event.

ERD620 : APPLICATIONS

FLOW CONTROL
Opening valves, closing valves with flow detection…
LEAK DETECTION
Leaking levels with flow detection…
CONTROL
Pressure contact elements…

ERD620 : FEATURES

• Flow measurement in direct or indirect testing
Wide flow measurement range
USA, S.I. and customer units
Measurement in standard or customised conditions
Recalculated flow at the nominal pressure
Measurement element fully integrated into one module
128 programs
Electronic regulator from vacuum to 10 bar
• Setting on line (via USB)
2 languages (English + other one)
• Data storage on internal memory or USB key

ENVIRONMENT :
ROHS standard

FLEXIBLE COMMUNICATION FORMAT :

RS232: Printer, modbus RTU
•Slave USB: PC supervision (WinAteq 300)
•Master USB: USB key to transfert (parameters, results, …)
•Option Fieldbus: Profibus, devicenet, profinet, Ethernet/IP, Modbus RTU

MEASUREMENT RANGES :

Flow measurement sensitivity from 0.1l/hr to 0.0001l/hr

ERD620 : SPECIFICATIONS

  • PHYSICAL

    • Weight : 8 Kg
    • Dimensions : (WxHxD) 250x150x360 mm
  • ELECTRICAL SUPPLY

    • 24VDC/2A or 100-240 VAC/50W
  • TEMPERATURE

    • Operating : + 5°C at + 45°C
    • Storage : 0°C at + 60°C
  • INTERFACE

    • Graphic color screen with simple and intuitive menu-driven operator controls
    • SMART KEY: programmable key with user’s functions
  • AIR SUPPLY

    • Clean and dry air
    • Air quality standard to be applied (ISO 8573-1)

ERD620 : OPTIONS

•9 inputs / 5 local outputs compatible with 5 series instruments
•6 inputs/ 6 outputs 24 V programmable for external automation
•External capillary: Close to the test part
• 2 pneumatic outputs for control of sealing connectors
Memory card for archiving results (400 000)

ERD620 : FACTSHEETS

Detailed information about the ERD620 including features, specifications, etc.

ERD620 : TECHNOLOGY

Sometimes a leak can be considered as a “small flow”, or a flow as a “big leak”. When your reject level is too high for other technologies, it may be necessary to use a laminar flow tester. A flow takes place between the pressure line and the leak hole of the part.
Our instrument features a laminar flow element across which our differential pressure transducer is connected.

Every flow generates a pressure difference between the inlet and outlet of the laminar flow element, and this variation is measured by the pressure transducer.
When the fluid (gas) enters the device 1, it moves through a calibrated flow tube 2 which causes a drop in pressure. The pressure drop is measured by a differential pressure sensor 3. The pressure of the part under test 5 is measured by the sensor 4.